Sonel Test Equipment
CMP-401 Clamp-on Meter
CMP-401 Clamp-on Meter
Regular price
$143.00
Regular price
Sale price
$143.00
Unit price
/
per
DC current measurement and AC current.
AC/DC voltage measurement up to 600 V.Resistance measurement and continuity test:
- continuity test with acoustic signalling (beeper) for resistance below 50.
Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement .
Diode test.
Additionally:
- safe, insulated measuring clamps,
- double molded housing,
- autoranging/manual range selection,
- DATA HOLD function, for holding measured values,
- backlit LCD,
- REL function,
- over range indication,
AUTO-OFF function.
--
-
DC current measurement and AC current. .
AC/DC voltage measurement up to 600 V.
Resistance measurement and continuity test:
- continuity test with acoustic signalling (beeper) for resistance below 50 Ω.
Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement
Diode test.
Additionally:
- safe, insulated measuring clamps,
- double molded housing,
- autoranging/manual range selection,
- „DATA HOLD” function, for holding measured values,
- backlit LCD,
- „REL” function,
- over range indication,
- „AUTO-OFF” function.
Electric security:
- measurement category: CAT III 600 V acc. to EN 61010 - 1:2004
- protection class acc. to EN 60529: IP40
Other technical data:
- power supply: 9 V battery type 6LR61
- display: 4000 counts, backlit LCD
- continuity test: I<0,5 mA, sound signal for R<50 Ω
- diode test: I = 0,3 mA, U0 = 1,5 V DC
- over range indication: 0L displayed
- sampling rate: 2 times per second
- input impedance: 10 MΩ (V DC and V AC)
- clamp size: opening 30 mm (1,2”)
- auto power OFF: approx. 30 min.
- dimensions: 197 x 70 x 40 mm
- weight: 183 g
- accordance with following standards: EN 61010 - 1:2004, EN 61010 - 2 - 032
- quality standard: ISO 9001
Rated operational conditions:
- operating temperature: 0...+40°C
- storage temperature: -20...+60°C
- operating humidity: max 80% up to 31°C; decreasing linearly to 50% at 40°C
- operating altitude: max 2000 m
Range Accuracy* -20,0...760°C ±(3% m.v. + 5°C) -4,0...1400°F ±(3% m.v. + 9°F)
Range Accuracy 10 Hz ... 10 kHz ±(1,5% m.v. + 2 digits)
Range Resolution Accuracy 40,00 A 0,01 A ±(2,5% m.v. + 8 digits) 400,0 A 0,1 A ±(2,8% m.v. + 5 digits)
Range Resolution Accuracy 40,00 A 0,01 A ±(2,5% m.v. + 5 digits) 400,0 A 0,1 A ±(2,8% m.v. + 5 digits)
Range Resolution Accuracy 400,0 mV 0,1 mV ±(1,5% m.v. + 30 digits) 4,000 V 0,001 V ±(1,5% m.v. + 5 digits) 40,00 V 0,01 V ±(1,5% m.v. + 5 digits) 400,0 V 0,1 V ±(1,5% m.v. + 5 digits) 600,0 V 1 V ±(2% m.v. + 5 digits)
Range Resolution Accuracy 400,0 mV 0,1 mV ±(0,8% m.v. + 2 digits) 4,000 V 0,001 V ±(1,5% m.v. + 2 digits) 40,00 V 0,01 V ±(1,5% m.v. + 2 digits) 400,0 V 0,1 V ±(1,5% m.v. + 2 digits) 600,0 V 1 V ±(2% m.v. + 2 digits)
Range Resolution Accuracy 400,0 Ω 0,1 Ω ±(1,0% m.v. + 4 digits) 4,000 kΩ 0,001 kΩ ±(1,5% m.v. + 2 digits) 40,00 kΩ 0,01 kΩ ±(1,5% m.v. + 2 digits) 400,0 kΩ 0,1 kΩ ±(1,5% m.v. + 2 digits) 4,000 MΩ 0,001 MΩ ±(2,5% m.v. + 3 digits) 40,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 digits)
Range Resolution Accuracy 40,00 nF 0,01 nF ±(4% m.v. + 20 digits) 400,0 nF 0,1 nF ±(3% m.v. + 5 digits) 4,000 nF 0,001 μF ±(3% m.v. + 5 digits) 40,00 nF 0,01 μF ±(3% m.v. + 5 digits) 100,0 nF 0,1 μF ±(4% m.v. + 10 digits)
„m.v.”- measured values