Skip to product information
1 of 6

Sonel Test Equipment

CMP-1006 Clamp-on Meter

CMP-1006 Clamp-on Meter

Regular price $175.00
Regular price Sale price $175.00
Sale Sold out
Shipping calculated at checkout.

 

(TRUE RMS) up to 1000 A.

 

Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)

 

AC/DC voltage measurement (TRUE RMS) up to 600 V.

 

Resistance measurement and continuity test:

 


    • continuity test with acoustic signalling (beeper) for resistance below 40.

 

Temperature measurement (Fahrenheit and Celsius units).

 

Frequency measurement.

 

Duty cycle measurement.

 

Diode test.

 

Additionally:

 


    • safe, insulated measuring clamps,

    • autoranging/manual range selection,

    • DATA HOLD function, for holding measured values,

    • backlit LCD,

    • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,

    • MAX/MIN function,

    • over range indication,

    • AUTO-OFF function.

"
--

Electric security:


    • measurement category: CAT III 600 V acc. to EN 61010 - 1:2004

    • protection class acc. to EN 60529: IP40


 

Other technical data:


    • power supply: 9 V battery type 6LR61

    • display: 6600 counts, backlit LCD

    • continuity test: threshold 40 Ω; test current < 0,5 mA

    • diode test: test current of 0,3 mA, typical open circuit voltage < 3 V DC, typical

    • low battery indication: BAT displayed

    • over range indication: 0L displayed

    • sampling rate: 2 times per second

    • INRUSH: integration time 100 ms

    • temperature sensor: type K thermocouple

    • input impedance: 10 MΩ (V DC and V AC)

    • AC bandwidth: 50...400 Hz (A AC and V AC)

    • auto power OFF: approx. 25 min.

    • dimensions: 229 x 80 x 49 mm

    • weight: 303 g

    • accordance with following standards: EN 61010 - 1:2004, EN 61010 - 2 - 032

    • quality standard: ISO 9001


 

Rated operational conditions:


    • internal clamp diameters: d1 = 36 mm/d2 = 52 mm

    • operating temperature: +5...+40°C

    • storage temperature: -20...+60°C

    • operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C

    • storage humidity: <80%

    • operating altitude: max 2000 m


 

AC/DC current measurement (TRUE RMS)

 
























Range Resolution Accuracy (DC) Accuracy (AC)
0...659,9 A 0,1 A ±(2,5% m.v. +5 dgt) ±(2,5% m.v + 8 dgt) for f = 50...60 Hz
660...1000 A 1 A ±(2,8% m.v. +8 dgt) ±(2,8% m.v. + 8 dgt) for f = 50...60 Hz

 

DC voltage measurement

 


























Range Resolution Accuracy
0...6,599 V 0,001 V ±(1,5% m.v. + 3 dgt)
6,60...65,99 V 0,01 V ±(1,5% m.v. + 3 dgt)
66,0...600,0 V 0,1 V ±(1,5% m.v. + 3 dgt)

 

AC voltage measurement (TRUE RMS)

 


























Range Resolution Accuracy
0...6,599 V 0,001 V ±(1,8% m.v. + 5 dgt) for f = 50...60 Hz
6,60...65,99 V 0,01 V ±(1,8% m.v. + 5 dgt) for f = 50...60 Hz
66,0...600,0 V 0,1 V ±(1,8% m.v. + 5 dgt) for f = 50...60 Hz

 

Resistance measurement

 









































Range Resolution Accuracy
0,0...659,9 Ω 0,1 Ω ±(1,0% m.v. + 4 dgt)
0,660...6,599 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
6,60...65,99 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
66,0...659,9 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
0,660...6,599 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
6,60...66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

Frequency measurement

 


























Range Resolution Accuracy
30,0...999,9 Hz 0,1 Hz ±(1.2% m.v. + 2 dgt) sensitivity:30...5 kHz:10 Vrms min. 5 kHz...15 kHz:40 Vrms min. for 20%...80% duty cycle
1,000...9,999 kHz 0,001 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30...5 kHz:10 Vrms min. 5 kHz...15 kHz:40 Vrms min. for 20%...80% duty cycle
10,00...15,00 kHz 0,01 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30...5 kHz:10 Vrms min. 5 kHz...15 kHz:40 Vrms min. for 20%...80% duty cycle

 

Temperature measurement

 





















Range Resolution Accuracy
-20...760°C 0,1°C ±(3,0% m.v. + 5°C)
-4...1400°F 0,1°F ±(3,0% m.v. + 9°F)

 

Duty cycle measurement

 
















Range Resolution Accuracy
10,0...94,9% 0,1% ±(1,2% m.v. + 2 dgt)



    • pulse width: 100μs...100 ms,

    • frequency range: 30 Hz...5 kHz,

    • sensitivity: 30 Hz...5 kHz: 10 Vrms, 5 kHz...15 kHz: 40 Vrms.



 

„m.v.”- measured value



 

View full details