{"product_id":"pvm-1530-pv-installation-meter","title":"PVM-1530 PV installation meter","description":"\u003cp\u003e\u003cstrong\u003eProfessional meter for photovoltaic installations up to 1500 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PVM-1530 is a pioneering meter for photovoltaic installations up to 1500 V with such a substantial number of measurement functions. It can be used for category 1 measurements according to EN 62446-1. It allows the measurement of the I-U curve for category 2 according to EN 62446-1. Furthermore, it also converts measured parameters into STC conditions according to EN IEC 60891. Comprehensive, yet simple to use, it flawlessly performs its tasks in monitoring the safety and efficiency parameters of photovoltaic (PV) installations.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"card-container  product-tabs\"\u003e\n\u003cdiv class=\"tabs\"\u003e\n\u003cul class=\"tabs-contents\"\u003e\n\u003cli class=\"tab tab-active\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv class=\"html-content sonel-content clearfix\"\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIt can be used for category 1 measurements according to EN 62446-1.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAllows the measurement of the I-U curve for category 2 according to EN 62446-1 and EN 61829.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIt allows the measurement of photovoltaic panels, including bifacial and high-efficiency panels.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAbility to define measurement procedures.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIt converts measured parameters into STC conditions according to EN IEC 60891 by cooperation with the IRM-1 solar radiation and temperature meter.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ereSYNC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunction – automatic completion of results with environmental parameters and their conversion to STC conditions after restoring connection with IRM-1.\u003c\/li\u003e\n\u003cli\u003eThe attachable radio interface ensures cooperation with the IRM-1 meter over long distances.\u003c\/li\u003e\n\u003cli\u003eBuilt-in Bluetooth and Wi-Fi for communication with external devices.\u003c\/li\u003e\n\u003cli\u003eLarge structured memory of measurements.\u003c\/li\u003e\n\u003cli\u003eLarge touchscreen for good visibility in bright sunlight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eMeasured parameters\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of I-U and P-U characteristics. Conversion to STC conditions.\u003c\/li\u003e\n\u003cli\u003eThe open circuit voltage of the PV panel or a chain of panels, up to 1500 V DC.\u003c\/li\u003e\n\u003cli\u003eRMS voltage of the AC network up to 1000 V with frequency measurement.\u003c\/li\u003e\n\u003cli\u003eShort circuit current of a PV panel or chain of panels - up to 40 A DC.\u003c\/li\u003e\n\u003cli\u003eInsulation resistance of PV panels - measuring voltage of 250, 500, 1000, 1500 V DC, simultaneous measurement of two values: R\u003csub\u003eISO+\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eISO-\u003c\/sub\u003e.\u003c\/li\u003e\n\u003cli\u003eInsulation resistance of AC circuits - measuring voltage 250, 500, 1000 V DC.\u003c\/li\u003e\n\u003cli\u003eResistance of protective conductors and equipotential bonding with ± 200 mA current.\u003c\/li\u003e\n\u003cli\u003eMeasurement of PV panels operating current and AC current - all with\u003c\/li\u003e\n\u003cli\u003eCMP-1015-PV meter.\u003c\/li\u003e\n\u003cli\u003eAC\/DC power measurement.\u003c\/li\u003e\n\u003cli\u003eTest of bypass diodes, automatic polarity detection.\u003c\/li\u003e\n\u003cli\u003eTest of blocking diodes with 1000, 1500 V DC voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eCat. 1 measurements and I-U characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eThe PVM-1530 is a pioneering meter for photovoltaic installations up to 1500 V with such a substantial number of measurement functions. Their selection is done via a touch screen. The screen is large, colorful and with strong backlight so that operation in full sunlight is not a problem. Extensive structural memory significantly reduces the time for preparing post-measurement documentation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eTightness and durability\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eLight meters perform well in harsh environmental conditions. The PVM-1530’s housing is rugged and tight when closed to easily ensure that the meter is protected during measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication and software\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eMeasurement data from the PVM-1530 can be transferred to a computer via cable or wireless communication. Saving the downloaded data to popular formats and printing is ensured by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSonel Reader\u003c\/strong\u003e. In order to generate a report on electric shock protection use the optional software:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSonel Reports Plus\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eTrouble? reSYNC!\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eIt may happen that in the course of measurements the PVM-1530 moves away from the IRM-1 so far, that communication between them is lost. If the measurements are continued, then after the connection is restored, the results will be automatically\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esupplemented with environmental parameters\u003c\/strong\u003e, which in the meantime were recorded by the IRM-1 in its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etemporary memory\u003c\/strong\u003e, and converted into STC conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-container  banner-section\"\u003e\u003c\/div\u003e","brand":"Sonel Test Equipment USA","offers":[{"title":"Default Title","offer_id":46571743707313,"sku":"WMGBPVM1530","price":11918.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0564\/0195\/2945\/files\/KeyfeaturesPVM-1530ES.webp?v=1767912573","url":"https:\/\/sonelusa.com\/products\/pvm-1530-pv-installation-meter","provider":"Sonel Test Equipment USA","version":"1.0","type":"link"}