{"product_id":"pat-96-portable-appliance-tester","title":"PAT-96 Portable Appliance Tester","description":"\u003cdiv class=\"html-content sonel-content clearfix description-simple\"\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-simple\"\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-simple\"\u003e\n\u003cp\u003e\u003cstrong\u003eModern testing of appliances, power tools and welding machines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure safe use of welding and electrical equipment with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSonel PAT-96 electrical equipment safety meter\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe Sonel PAT-96 advanced meter is perfect for control measurements of welding machines and other electrical devices. The instrument allows to measure parameters having an impact on the safe use of the equipment, such as resistance of protective conductors, insulation resistance, continuity of connections, leakage currents, power, RCD and PRCD. The PAT-96 model is especially dedicated to testing welding equipment according to the EN 60974-4 standard. It allows, among other things, to check the rated voltage of welding equipment in no-load condition, the welding circuit leakage current and the primary leakage current.\u003c\/p\u003e\n\u003cp\u003eThe Sonel PAT-96 electrical equipment safety meter will come in handy in those areas where safety is of particular importance. Reliable wherever welders, power tools, three-phase appliances or domestic appliances need to be inspected.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/k5jDwPv1zo0?si=BuZGKQ1l1l9aEq2e\" title=\"YouTube video player\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eSonel MeasureEffect™\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eThe meter is a part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSonel MeasureEffect™\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It is a comprehensive system that enables you to take measurements, store and manage data, and provides multi-level control of your instruments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cul\u003e\n\u003cli\u003ePower supply 95...265 V\u003c\/li\u003e\n\u003cli\u003eMeasurement of devices with 110 V and 230 V 50\/60 Hz power supply\u003c\/li\u003e\n\u003cli\u003eMeasuring system that enables:\n\u003cul\u003e\n\u003cli\u003emeasurement of welding equipment parameters:\n\u003cul\u003e\n\u003cli\u003erated voltage of welding devices in no-load condition,\u003c\/li\u003e\n\u003cli\u003ewelding circuit leakage current,\u003c\/li\u003e\n\u003cli\u003eprimary leakage current,\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eprotective conductor resistance measurement,\u003c\/li\u003e\n\u003cli\u003emeasurement of insulation resistance in three points,\u003c\/li\u003e\n\u003cli\u003emeasurement of substitute, differential and touch leakage current,\u003c\/li\u003e\n\u003cli\u003efunctional test,\u003c\/li\u003e\n\u003cli\u003etest of RCD and PRCD switches,\u003c\/li\u003e\n\u003cli\u003e...and much more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in measurement procedure wizard\u003c\/li\u003e\n\u003cli\u003eIntuitive user interface\u003c\/li\u003e\n\u003cli\u003eCooperation with a label printer and QR code scanner\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eSonel PAT-96 is an ideal choice for professionals involved in the maintenance and repair of power tools and other appliances. Thanks to its accurate testing, it provides a detailed analysis of the technical condition of the equipment under examination. It guarantees both the safety of users and the long-term maintenance of equipment in optimal technical condition. Developed on the basis of the experience gained, the Sonel PAT-96 tester is designed for both field and industrial challenges.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eVersatility\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eThe device is used wherever safety is the most important thing. Ideally suited to situations where it is necessary to check welders, power tools, three-phase devices and household appliances.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eWelding machines\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003ePAT-96 was created for testing welding equipment in compliance with EN 60974-4 standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eCapabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eThanks to the extensive measuring part, PAT-96 enables comprehensive checking of electrical devices. The touch screen and autoprocedures section make testing quick and efficient. The automatic procedure wizard means even more flexibility for the instrument. The meter has a built-in help system.\u003c\/p\u003e\n\u003cp\u003eThe meter cooperates with a label printer and QR scanner, which greatly facilitates the recordkeeping of tools. The following printouts are available:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003einitial measurement report,\u003c\/li\u003e\n\u003cli\u003eQR code, where, which stores unique data to identify the device in the database.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese data can be read and added to the meter memory using the optional QR code scanner.\u003c\/p\u003e\n\u003cp\u003eThe whole picture is complemented by a compact and durable housing. It provides instrument protection during both measurements and transport.Capabilities\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eThe memory has a tree structure, built from folders, objects and devices. For each device tested it contains its description, location of measurements, customer data and registration number.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eThe instrument can be used to test equipment according to standards, among others:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50699\u003c\/li\u003e\n\u003cli\u003eEN 50678\u003c\/li\u003e\n\u003cli\u003eEN 60974-4\u003c\/li\u003e\n\u003cli\u003eVDE 0701-0702\u003c\/li\u003e\n\u003cli\u003eVDE 0404-1\u003c\/li\u003e\n\u003cli\u003eVDE 0404-2\u003c\/li\u003e\n\u003cli\u003eEN 60745-1\u003c\/li\u003e\n\u003cli\u003eEN 62841\u003c\/li\u003e\n\u003cli\u003eEN 60335-1\u003c\/li\u003e\n\u003cli\u003eEN 60950\u003c\/li\u003e\n\u003cli\u003eEN IEC 62368-1\u003c\/li\u003e\n\u003cli\u003eAS\/NZS 3760\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"table_caption\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003ctable class=\"rwd_table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement functions\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eResistance of protective conductor (PE)\u003c\/strong\u003e\u003cbr\u003eI = 200 mA \/ 10 A \/ 25 A\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 19.99 Ω\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003efrom 1 mΩ\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003efrom ±(3% m.v. + 4 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003e\n\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003eU\u003csub\u003eISO\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 100 V \/ 250 V \/ 500 V \/ 1000 V\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 599.9 MΩ\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003efrom 1 kΩ\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(5% m.v. + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003e\u003cstrong\u003eCurrent (clamp measurement)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 24.9 A\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003efrom 1 mA\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(5% m.v. + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003e\u003cstrong\u003eVisual test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e✓\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003e\u003cstrong\u003eContinuity check of protective conductor (PE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e✓\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003e\u003cstrong\u003eInsulation resistance measurement at three points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e✓\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003e\u003cstrong\u003eIEC cable test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e✓\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003e\u003cstrong\u003eFunctional test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eApparent power S\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 3.99 kVA\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003efrom 1 VA\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(5% m.v. + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eActive power P\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 3.99 kW\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003efrom 1 W\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(5% m.v. + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eReactive power Q\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 3.99 kvar\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003efrom 1 var\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(5% m.v. + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003ePower Factor (PF)\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 1.00\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.01\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(10% m.v. + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eCurrent consumption for power measurement\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 15.99 A\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.01 A\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(2% m.v. + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eTHD for voltage and current\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 999.9%\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.1%\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(5% m.v. + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003ecosφ\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 1.0\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.1\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(5% m.v. + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003e\u003cstrong\u003eVoltage measurement for welding machines\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eRMS voltage U\u003csub\u003eRMS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 170.0 V\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(2.5% m.v. + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eDC and AC peak voltage\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 240.0 V\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(2.5% m.v. + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eVoltage U\u003csub\u003e0\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 240.0 V\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(2.5% m.v. + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003e\u003cstrong\u003eLeakage current measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eWelding circuit leakage current I\u003csub\u003eL\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 14.99 mA\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.01 mA\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(5% m.v. + 2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eLeakage current of the welding machine’s primary circuit I\u003csub\u003eP\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 14.99 mA\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.01 mA\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(5% m.v. + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003ePE leakage current and differential leakage current\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 19.9 mA\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.01 mA\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(5% m.v. + 2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eSubstitute leakage current\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 19.9 mA\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.01 mA\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(5% m.v. + 2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eTouch leakage current\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 4.999 mA\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.001 mA\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(5% m.v. + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003e\u003cstrong\u003eRCD and PRCD switch test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eMeasurement of RCD parameters according to IEC 61557\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 300 ms\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e1 ms\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(2% m.v. + 2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eMeasurement of RCD tripping current I\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003efor sinusoidal residual current (AC type)\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 30 mA\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.1 mA\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±5% I\u003csub\u003eΔn\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003e\u003cstrong\u003eMeasurement of power network parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 265.0 V\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(2% m.v. + 2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-header=\"Measurement functions\" title=\"Measurement functions\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-header=\"Range\" title=\"Range\"\u003eup to 65.0 Hz\u003c\/td\u003e\n\u003ctd data-header=\"Resolution\" title=\"Resolution\"\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd data-header=\"Accuracy\" title=\"Accuracy\"\u003e±(2% m.v. + 2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"table_caption_bottom\"\u003e\n\u003cp class=\"regular-text text\"\u003e \u003c\/p\u003e\n\u003cp\u003em.v. – measured value\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sonel Test Equipment","offers":[{"title":"Default Title","offer_id":46594332885169,"sku":"WMGBPAT96","price":4637.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0564\/0195\/2945\/files\/PAT-96F.webp?v=1768516788","url":"https:\/\/sonelusa.com\/products\/pat-96-portable-appliance-tester","provider":"Sonel Test Equipment USA","version":"1.0","type":"link"}