{"product_id":"mic-2511-epa-insulation-resistance-meter","title":"MIC-2511 EPA Insulation Resistance Meter","description":"\u003cdiv\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-simple\"\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-simple\"\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure insulation resistance up to 2 TΩ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe functional insulation resistance meter Sonel MIC-2511\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emay be used to measure the insulation resistance using test voltage\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eup to 2500 V\u003c\/strong\u003e. It surprises with numerous functions hidden in a neat and handy form. Due to its parameters, its robust casing with IP65 protection level, its low battery power consumption and the possibility of recharging during measurements, the meter is a reliable tool that can be used in many areas. It is ideal for checking industrial installations and catenary networks, and is also successfully used in residential buildings. The advantages of this equipment are especially appreciated by electricians working in maintenance, testing motors, cables and street lighting. The Sonel MIC-2511 meter is also useful for measurements during construction and maintenance of photovoltaic installations. It is a reliable solution created for the needs of telecommunications network installers and heating network operators, facilitating the control of the alarm system of pre-insulated pipes.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/videoseries?list=PLICwL6VglKz1c-wYGmhZRdYwzG66hRTPH\" title=\"YouTube video player\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eThe product was developed to fully or partially meet the standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 61340-2-3\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eElectrostatics - Part 2-3: Methods of test for determining the resistance and resistivity of solid planar materials used to avoid electrostatic charge accumulation\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC 61340-4-1\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eElectrostatics - Part 4-1: Standard test methods for specific applications - Electrical resistance of floor coverings and installed floors\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC 61340-4-3\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eElectrostatics - Part 4-3: Standard test methods for specific applications - Footwear\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC 61340-4-5\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eElectrostatics - Part 4-5: Standard test methods for specific applications - Methods for characterizing the electrostatic protection of footwear and flooring in combination with a person\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC 61340-4-6\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eElectrostatics - Part 4-6: Standard test methods for specific applications - Wrist straps\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC 61340-4-7\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eElectrostatics - Part 4-7: Standard test methods for specific applications - Ionization\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC 61340-4-9\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eElectrostatics - Part 4-9: Standard test methods for specific applications - Garments\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC 61340-5-1\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eElectrostatics - Part 5-1: Protection of electronic devices from electrostatic phenomena - General requirements\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC TR 61340-5-2\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eElectrostatics - Part 5-2: Protection of electronic devices from electrostatic phenomena - User guide\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC 61340-5-3\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eElectrostatics - Part 5-3:\u003cspan\u003e \u003c\/span\u003e\u003c\/em\u003e\u003cem\u003eProtection of electronic devices from electrostatic phenomena - Properties and requirements classification for packaging intended for electrostatic discharge sensitive devices\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC 62631-3-1\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eDielectric and resistive properties of solid insulating materials - Part 3-1: Determination of resistive properties (DC methods) - Volume resistance and volume resistivity - General method\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eHD 60364-6\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eLow-voltage electrical installations - Part 6: Verification\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC 1081\u003cspan\u003e \u003c\/span\u003e\u003cem\u003ePneumatic instruments driven by associated process gas - Safe installation and operating procedures - Guidelines\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eSonel MeasureEffect™\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eThe meter is a part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSonel MeasureEffect™\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It is a comprehensive system that enables you to take measurements, store and manage data, and provides multi-level control of your instruments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement voltage within the range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10…2500 V\u003c\/strong\u003e: selected from 10 V, 25 V, 100 V, 250 V, 500 V, 1000 V, 2500 V or 10…2500 V selected in steps of 10 V\u003c\/li\u003e\n\u003cli\u003eInsulation resistance measurements with a voltage of 10 V of the supervisory loop of fire alarm systems\u003c\/li\u003e\n\u003cli\u003eTesting surge protecting devices (SPD)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCharts plotted on display during measurements\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMeasurements in electrostatic protected areas (EPA)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCorrection of insulation resistance result to reference temperature\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eContinuous reading of measured insulation resistance or leakage current\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge of the measured object’s capacitance upon completion of insulation resistance measurement\u003c\/li\u003e\n\u003cli\u003eSound signaling of five-second time intervals, facilitating capture of time characteristics\u003c\/li\u003e\n\u003cli\u003eTiming of measurement times T\u003csub\u003e1\u003c\/sub\u003e, T\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand T\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003efor measurement of one or two absorption coefficients (Ab1, Ab2 or DAR, PI) within the range of 1… 600 s\u003c\/li\u003e\n\u003cli\u003eAutomatic measurement of all resistance combinations of 3-, 4- and 5-core cords and power cords by means of the optional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAutoISO-2511\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadapter\u003c\/li\u003e\n\u003cli\u003eReading of actual measurement voltage during measurement\u003c\/li\u003e\n\u003cli\u003eMeasurement current\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u0026lt;2 mA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProtection against measurement of live objects\u003c\/li\u003e\n\u003cli\u003eTwo- or three-lead method of insulation resistance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional features\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of leakage current during measurement of R\u003csub\u003eISO\u003c\/sub\u003e\n\u003c\/li\u003e\n\u003cli\u003eCapacitance measurement during measurement of R\u003csub\u003eISO\u003c\/sub\u003e\n\u003c\/li\u003e\n\u003cli\u003eLow-voltage measurement of circuit continuity and resistance\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTemperature measurement (with the use of the optional ST-1 temperature probe)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMeasurement of direct and alternating voltages within the range of 0...1500 V\u003c\/li\u003e\n\u003cli\u003e9999-entry memory, data transmission to PC via USB cable\u003c\/li\u003e\n\u003cli\u003ePower supplied by rechargeable battery\u003c\/li\u003e\n\u003cli\u003eBacklit keyboard\u003c\/li\u003e\n\u003cli\u003eThe instrument meets the requirements laid down by standard EN IEC 61557\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eThis insulation resistance meter is a device with a wide range of applications. It may be successfully operated both in residential construction industry and for inspecting industrial systems or traction networks. Due to its characteristics – excellent performance, low power consumption from batteries, the option of charging during measurements, convenience of use and a high ingress protection level – it is often used by electricians working in maintenance teams, testing motors, cables, street lighting or at the construction and maintenance of photovoltaic systems. The device perfectly matches the needs of installers of telecommunications networks and operators of district heating networks, where the inspection of alarm system on insulated pipes is necessary.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eThe meter may be used to measure the insulation resistance using test voltage up to 2500 V. When testing cables, it automatically discharges their load at the moment of completing the measurement. Together with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePRZ-2 (kit for measuring resistance in zones with ESD protection)\u003c\/strong\u003e, it is a comprehensive tool for technicians dealing with the protection of plants against static electricity.\u003c\/p\u003e\n\u003cp\u003eThe device allows safety control of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eresidential, commercial and industrial electrical installations\u003c\/strong\u003e. Measurements can be easily automated with\u003cbr\u003e\u003cstrong\u003eAutoISO-2511\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadapter for automatic insulation resistance test of 3-, 4- and 5-conductor cables, without switching.\u003c\/p\u003e\n\u003cp\u003eMIC-2511 allows user to measure the continuity of protective conductors and equipotential bondings with current exceeding 200 mA in both directions. The meter has a built-in voltmeter of AC and DC voltages in the range of up to \u003cstrong\u003e1500 V\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eExtensive memory allows the device to record and send to a computer nearly\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10,000 measurement results\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in help system\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eThe device has built-in help screens with measurement diagrams. Thanks to this you can easily and quickly check and make sure how to connect to a given system depending on the type of performed measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"html-content sonel-content clearfix description-item\"\u003e\n\u003cdiv class=\"description-item-label\"\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication and software\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description-item-content\"\u003e\n\u003cp\u003eYou can easily transfer measurement data to your computer via USB port. In order to generate a report on measurements for electric shock protection, use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSonel Reports PLUS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware. Saving the downloaded data to the simplest formats and printing is provided by free\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSonel Reader\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sonel Test Equipment","offers":[{"title":"Default Title","offer_id":46591955632305,"sku":"WMGBMIC2511EPA","price":4032.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0564\/0195\/2945\/files\/MIC-2511EPAL.webp?v=1768411445","url":"https:\/\/sonelusa.com\/products\/mic-2511-epa-insulation-resistance-meter","provider":"Sonel Test Equipment USA","version":"1.0","type":"link"}